Epoxy Cast Resin Transformer Tap Range ±2.5%, ±5% Frequency 50hz, 60hz Impedance Voltage 4-8% High Voltage Connection

Epoxy Cast Resin Transformer Tap Range ±2.5%, ±5% Frequency 50hz, 60hz Impedance Voltage 4-8% High Voltage Connection - Image 1
Epoxy Cast Resin Transformer Tap Range ±2.5%, ±5% Frequency 50hz, 60hz Impedance Voltage 4-8% High Voltage Connection - Image 1

Negotiable


Product information

High-quality Epoxy Cast Resin Transformer Tap Range ±2.5%, ±5% Frequency 50hz, 60hz Impedance Voltage 4-8% High Voltage Connection supplied by Power Engineers Company. Bulk wholesale pricing is negotiable. Inquiry for latest prices.

Rated Voltage Low Voltage:

0.48 - 4.16 Kv

Power Capacity Single Phase:

20 - 2,000 Kva

Impedance Voltage:

4-8%

Power Capacity Three Phase:

50 - 10,000 Kva

Frequency:

50hz, 60hz

High Voltage Connection:

Delta

Environmentally Safe:

Does Not Emit Oil Or Toxic Gases; Recommended Replacement For Pcb-filled Transformers

Failure Rate:

Less Than 5% Of Standard Dry Type Transformers In Some Applications

Specifications

Rated Voltage Low Voltage:

0.48 - 4.16 Kv

Power Capacity Single Phase:

20 - 2,000 Kva

Impedance Voltage:

4-8%

Power Capacity Three Phase:

50 - 10,000 Kva

Frequency:

50hz, 60hz

High Voltage Connection:

Delta

Environmentally Safe:

Does Not Emit Oil Or Toxic Gases; Recommended Replacement For Pcb-filled Transformers

Failure Rate:

Less Than 5% Of Standard Dry Type Transformers In Some Applications

Noise Level:

Low Noise Due To Resin Encapsulation, Core Cutting, And Coil Support Elastic Structure

Maintenance Free:

No Liquid Level Checking, No Yearly Dielectric Test For Moisture Absorption; Occasional Visual Or Infra-red Thermal Inspection Recommended

Fire Resistant:

Self Fire-extinguishing And Fire Resistant; Flame Extinguishes Itself After 15 Seconds When Ignited With Acetylene Torch For 2 Minutes

Trade Term:

To be discussed

Payment Term:

To be discussed

Rated Voltage High Voltage:

Up To 36 Kv

Low Voltage Connection:

Wye With Neutral Point

Tap Range:

±2.5%, ±5%

Business Details

Country:

India

Business Types:

Not specified

Main Markets:

Not specified

Main Products:

Not specified

Year Established:

2010

Annual Revenue Amount:

Not specified

Numbers Of Employees:

Not specified

Preferred Payment Term:

Not specified

Preferred Trade Term:

Not specified

Port Of Loading:

Not specified

Product descriptions from the supplier

We manufacture, export and supply Epoxy Cast Resin Transformers in various specifications. The Epoxy Cast Resin Transformers are designed to be Fire resistant, Maintenance Free and Environmentally Safe. Besides, the Epoxy Cast Resin Transformers generate low noise and are very cost-efficient. Made using advanced technology, the Epoxy Cast Resin Transformers are resistant to failures, thus serve as dependable power supply systems.

 


Characteristics
Fire resistant : Cast Resin transformers have an inherently safe characteristic of self fire-extinguishing and fire resistance. So there would be no fear of spread of fire even if a fire took place in nearby equipment.


The transformers can be used indoors without fear of fire, and it is not necessary to provide additional measures for safety.

  • Ignited for 2 minutes on the surface of cast coil with acetylene torch.
  • As the torch was removed from the surface of burning resin.
  • The flame extinguished by itself after 15 seconds.


Maintenance Free : Maintenance is almost completely eliminated. No checking of liquid level and no yearly dielectric test for moisture absorption is required. Due to the smooth coil surfaces, heavy dirt and dust build up is eliminated even under the worst circumstances. The recommended routine maintenance is an occasional visual or Infra-Red thermal inspection.


Environmentally Safe : Power-Cast transformers will not emit oil or toxic gases into the atmosphere. Therefore, they do not pollute the environment and are recommended strongly as a replacement for askarel filled (PCB) transformers. PCB is poisonous, chemically aggressive and can discharge dangerous gases at elevated temperatures.


Low Noise : The encapsulation of the core in a special resin and the design of the clamping mechanism have provided an appreciable noise reduction. Noise is also reduced due to the sound suppressing effect of the elaborate core cutting and the coil support elastic structure.


Cost Saving : If the advantage of Power - Cast transformers is taken into consideration at the planning stage, the overall costs of a power supply system can often be considerably reduced. They are sufficiently compact for convenient installation in a building where space is generally limited and have much smaller power loss than oil immersed and dry-type transformers. Total costs are lower even though cast resin transformers may be more expensive than other transformers. Cost savings add low maintenance and longer operating life in all conditions.


Fewer Failures : Standard Insurance Company studies have shown failure rates in cast coil transformers to be less than 5% that of standard dry type transformers in some applications.

Specifications
Power-Cast transformers are available with specification as follows :

Rated Voltage
  • HV coil : Up to 36KV
  • LV coil : 0.48-4.16 KV
*Power-Cast transformers with multiple high voltage connections can also be supplied.
Tap Range
  • Standard : ±2.5%, ±5%
* Other ratings are available by arrangement.
Power Capacity
  • Single phase : 20 - 2,000 KVA
  • Three phase : 50 - 10,000 KVA
  • Frequency : 50Hz, 60Hz
  • Typical % impedance voltage : 4-8%.
Connections
  • HV coil : Delta
  • LV coil : Wye with neutral point
* Other connections are available to meet requirements.

User Reviews

Like
Write a review
File a complaint

Supplier Review

Summary by Vivian

TRUST STARS

3.8/5

0 Reviews

Company Verification

1/4

Profile Completeness

44%

Avg. Product Score

0/5

Responsiveness

0%

Certification

-

Related searches

Frequently Asked Questions (FAQs)


You can contact verified India supplier Power Engineers Company through platforms like Freshdi.com to purchase Epoxy Cast Resin Transformer Tap Range ±2.5%, ±5% Frequency 50hz, 60hz Impedance Voltage 4-8% High Voltage Connection. For direct inquiries, please contact Power Engineers Company, the company’s representative. The supplier has a 3.8-star rating on Freshdi and has verified phone number. You’ll receive product details, pricing, and shipping terms directly from supplier.


Epoxy Cast Resin Transformer Tap Range ±2.5%, ±5% Frequency 50hz, 60hz Impedance Voltage 4-8% High Voltage Connection is sourced from India and meets international export standards. Key specifications include: Fire Resistant: Self Fire-extinguishing And Fire Resistant; Flame Extinguishes Itself After 15 Seconds When Ignited With Acetylene Torch For 2 Minutes, High Voltage Connection: Delta, Impedance Voltage: 4-8%, Power Capacity Three Phase: 50 - 10,000 Kva, Maintenance Free: No Liquid Level Checking, No Yearly Dielectric Test For Moisture Absorption; Occasional Visual Or Infra-red Thermal Inspection Recommended, Failure Rate: Less Than 5% Of Standard Dry Type Transformers In Some Applications, Trade Term: To be discussed, Payment Term: To be discussed


The supplier Power Engineers Company offers Epoxy Cast Resin Transformer Tap Range ±2.5%, ±5% Frequency 50hz, 60hz Impedance Voltage 4-8% High Voltage Connection at negotiation.

You are viewing details for Epoxy Cast Resin Transformer Tap Range ±2.5%, ±5% Frequency 50hz, 60hz Impedance Voltage 4-8% High Voltage Connection. The information provided here is either posted directly by the supplier, who is responsible for its accuracy, or collected by Freshdi AI from publicly available sources. Freshdi strives to make product information as useful and reliable as possible, but we do not guarantee complete accuracy. If you notice any incorrect or misleading details, please use the Report Product option so our team can review and address it quickly.

Negotiable

Min. order: Negotiable

1 yrs

India FlagIndia

3.8

Power Engineers Company

Year Established: 2010

Visit Store