Upgrade Membership

For Supplier

supplier help center

Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze

Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze - Image 1
Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze - Image 2
Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze - Image 3
Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze - Image 4
Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze - Image 5
Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze - Image 6
Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze - Image 1
Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze - Image 2
Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze - Image 3
Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze - Image 4
Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze - Image 5
Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze - Image 6

1 Set

$37,387

Product information

High-quality Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze supplied by Macylab Instruments Inc.. Bulk wholesale pricing is $37,387 per Set with a minimum order of 1 Set. Inquiry for latest prices.

Warranty:

1 Year

Package Size:

180.00cm * 80.00cm * 85.00cm

Package Gross Weight:

350.000kg

Specification:

360*

Production Capacity:

50PCS/Month

HS Code:

9027300090

Transport Package:

Carton

Origin:

China

Specifications

Warranty:

1 Year

Package Size:

180.00cm * 80.00cm * 85.00cm

Package Gross Weight:

350.000kg

Specification:

360*

Production Capacity:

50PCS/Month

HS Code:

9027300090

Transport Package:

Carton

Origin:

China

Refund Policy:

Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

Principle:

Classic Spectrometer

Shipping Cost:

Contact the supplier about freight and estimated delivery time.

Customized:

Customized

Trade Term:

FOB, CIF, CFR

Dispersive Element:

Grating Spectrometer

Advantage:

High Resolution

Model NO.:

ICP-6800

Payment Term:

LC, T/T, D/P, PayPal, Western Union, Small-amount payment

Trademark:

Macylab

Light Number:

Monochromator

After Sales Service:

Online Technical Support

Certification:

RoHS, ISO9001, CE

Port Of Loading:

Shanghai Port

Detection Method:

Spectrophotometer

Payment Methods:

Support payments in USD

Wavelengths:

Visible Spectrometer

Business Details

Country:

China

Business Types:

Not specified

Main Markets:

Not specified

Main Products:

Year Established:

2012-02-21

Annual Revenue Amount:

Not specified

Numbers Of Employees:

43

Preferred Payment Term:

LC, T/T, D/P, PayPal, Western Union, Small-amount payment

Preferred Trade Term:

FOB, CIF, CFR

Port Of Loading:

Shanghai Port

Certificates:

RoHS

Product descriptions from the supplier

Detailed Product Description

Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph AnalyzeInductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph AnalyzeInductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph AnalyzeInductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze

Shipping/Storage Ambient Temperatur: 15ºC-25ºC Atmospheric Pressure: ≤70%
Power Supply: 220±10V 50-60MHz Working Humidity: ≤70%
Working Temperature: Away From The Instrument, Electric Field: E<2V/m Name: ICP-6800 Inductively Coupled Plasma Optical Emission Spectrophotometer
High Light:

inductively coupled plasma optical emission spectrophotometer

,
ICP

-6800 inductively coupled plasma optical emission spectrophotometer

ICP-6800 Inductively Coupled Plasma Optical Emission Spectrometer(standard)
Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze
 
ICP-6800 Inductively Coupled Plasma Optical Emission Spectrometer(standard)

 

 Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.
 At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.
 

Main Features

 


Performance stability
The use of all-solid-state rf power supply, with small size, high efficiency, stable output power, with a variety of protection functions and many other advantages, the load using fully automatic matching technology, matching speed, improve the efficiency of the use of power supply and the stability of the instrument, and make the whole ignition process simple and convenient.

 

Injection automation

The instrument is equipped with a four-channel twelve-roller high-precision peristaltic pump, which can guarantee the precision of injection and prevent liquid accumulation at the same time. The speed of the peristaltic pump can be adjusted continuously to meet various test requirements of customers.

 

Flow control parameters

Adopt imported high precision mass flow controller.

 

High precision constant temperature system

The whole optical path of adopt the precision constant temperature protection system. The temperature control can be set in real time according to the actual ambient temperature of the customer's laboratory, without the need to turn on the air conditioner continuously for a long time. Temperature control precision ≤±0.1%, precision constant temperature protection system to ensure the stability of the optical path and makes the test data more stable.

Product Parameters

 

RFPower technical parameter

 

Circuit type

solid-state RF Power supply, with function of automatch

Frequercy

27.12MHz±0.05%

Frequency Stablity

<0.1%

Power Output

800W-1200W

Power Output Stability

<0.3%

Escaped RF radiation

30cm away from the instrument, electric fiekd: E<2V/m

Sampling System Technical Parameter

 

Output working coil imer diameter

25mm

Torpue tube

Three concentric, extemal diameter 20mm

Coaxial nebulizer

Outer dameter 6mm

Double barrel atomizing chamber

Outer diameter 34mm

 

Gas Flow Controls

 

Plasma Argon Flowmeter

(100-1000)L/h(1.6-16L/min)

Auxiliary Argon Fiowmeter

(10-100)L/h(0.16-1.66L/min)

Auxiliary Carrier Argon Flowmeter

(10-100)L/h(0.16-1.66L/min)

Pressune Maintaining Value

(0-0.4MPa)

Cooling Water:Temperature

20-25ºC,Rate of Flow>5L/min,Hydraulic Pressure>0.1MPa

 

Spectrometer

 

Optics

Czerny-Turner type

Focal length

1000 mm

Grating

Ion Beam Etching Holographic Grating, 3600L/mm or 2400L/mm

Reciprocal linear dispersion

0.26nm/mm

Resolution

≤0.007nm(3600 line grating); ≤0.015nm(2400 line grating)

Wavelength range

3600 line grating:(190nm~500) nm; 2400 line grating:(190nm~800) nm

Minimum pace of stepping motor

≤0.0006 nm

Exit Slit

12μm

Entrance Slit

10μm

 

Photoelectric Converter Performance

 

Photomultiplier tube specification

R293/R928

Negative HV on PMT

0-1000V

Stability

<0.05%

Overall Performance

Wavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating)

Repeatability: RSD(Relative Standard Deviation)≤1.5%

Stability: RSD(Relative Standard Deviation) ≤2%

Detection Limits (µg/L):

 

Element WL(nm) Limit   Element WL(nm) Limit
La 408.672 <3.0   Cr 267.716 <5.0
Ce 413.765 <5.0   Al 396.152 <5.0
Pr 414.311 <5.0   Zr 343.823 <5.0
Nd 401.225 <5.0   Ag 328.068 <3.0
Sm 360.946 <10.0   Sr 407.771 <1.0
Eu 381.967 <1.0   Au 242.795 <5.0
Gd 342.247 <10.0   Pt 265.945 <5.0
Tb 350.917 <3.0   Pd 340.458 <5.0
Dy 353.170 <3.0   Ir 224.268 <10.0
Ho 345.600 <3.0   Rh 343.489 <10.0
Er 337.271 <3.0   Ru 240.272 <5.0
Tm 313.126 <3.0   Ba 455.403 <1.0
Yb 369.419 <1.0   As 228.812 ≤15
Lu 261.541 <3.0   Sb 206.833 ≤15
Y 371.030 <1.0   Bi 223.061 ≤10
Sc 335.373 <1.0   Hg 253.652 ≤15
Ta 226.230 <5.0   Pb 220.353 ≤15
Nb 313.340 <5.0   Ga 294.364 ≤10
Mn 257.610 <3.0   Se 203.985 ≤10
Mg 279.553 <1.0   Sn 242.949 ≤20
B 249.773 <10.0   Te 214.281 ≤10
Zn 213.856 <3.0   Ta 226.230 ≤5.0
Co 228.616 <3.0   Th 283.730 ≤10
Si 251.611 <10.0   Tl 276.787 ≤30
Ni 232.003 <5.0   Re 227.525 ≤5
Cd 226.502 <3.0   Ge 209.426 ≤15
Fe 239.562 <3.0   Os 225.585 ≤1
Ca 393.366 <1.0   W 207.911 ≤10
Mo 281.615 <5.0   Cu 324.754 <3.0
V 310.230 <5.0   Li 670.784 ≤3
Be 313.041 <1.0   Na 588.995 ≤20
Ti 334.941 <3.0   K 766.490 ≤60

plication F

Application Fields

Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.

At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.

 

Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze

 

Application Fields

Certificates


Application FieldsApplication Fields

Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze

 

Company Profile

 

Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze

 

Exhibitions
Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze
Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze
Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze
 

 

Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze

 

                                                                                                                              Application Field                                                                                                                           Certificate                                                                                                      Company profile                                                                        

 

User Reviews

Like
Write a review
File a complaint

Supplier Review

Summary by Vivian

TRUST STARS

3.6/5

0 Reviews

Company Verification

0/4

Profile Completeness

67%

Avg. Product Score

0/5

Responsiveness

0%

Certification

RoHS

Related searches

Frequently Asked Questions (FAQs)


You can contact verified China supplier Macylab Instruments Inc. through platforms like Freshdi.com to purchase Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze. For direct inquiries, please contact Ms. Alice, the company’s representative. The supplier has a 3.6-star rating on Freshdi and has verified. You’ll receive product details, pricing, and shipping terms directly from supplier.


For Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze, Macylab Instruments Inc. accepts LC, T/T, D/P, PayPal, Western Union, Small-amount payment as the preferred payment method, the trade term is FOB, CIF, CFR, and shipments are typically arranged from port Shanghai Port, ensuring secure and timely international delivery.


The supplier Macylab Instruments Inc. offers Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze at negotiation.


Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze is sourced from China and meets international export standards. Key specifications include: After-Sales Service: Online Technical Support, Transport Package: Carton, Origin: China, Model NO.: ICP-6800, Light Number: Monochromator, Specification: 360*, Trade Term: FOB, CIF, CFR, Payment Term: LC, T/T, D/P, PayPal, Western Union, Small-amount payment

You are viewing details for Inductively Coupled Plasma Mass Spectrometry Spectrometer Spectrograph Analyze. The information provided here is either posted directly by the supplier, who is responsible for its accuracy, or collected by Freshdi AI from publicly available sources. Freshdi strives to make product information as useful and reliable as possible, but we do not guarantee complete accuracy. If you notice any incorrect or misleading details, please use the Report Product option so our team can review and address it quickly.

$37,387

/ Set

Min. order: 1 Set

Macylab Instruments Inc.
1 yrs

China FlagChina

3.6

Ms. Alice

Year Established: 2012-02-21