Share on
1 Piece
$1,0001 Piece
$1Product information
High-quality Toxic Combustible Vehicle Exhaust Gas Analyzer supplied by Shandong China Coal Industrial & Mining Supplies Group Co., Ltd.. Bulk wholesale pricing ranges from $1 to $1,000 per Piece with a minimum order of 1 Piece. Inquiry for latest prices.
0~10000X10-6 (Ppm)Vol
0~10X10-2 (%)Vol
0~20X10-2 (%)Vol
0~25X10-2 (%)Vol
0~40000 10-6 (Ppm)Vol
1 Set
1000 Sets Per Month
24.000kg
0~10000X10-6 (Ppm)Vol
0~10X10-2 (%)Vol
0~20X10-2 (%)Vol
0~25X10-2 (%)Vol
0~40000 10-6 (Ppm)Vol
1 Set
1000 Sets Per Month
24.000kg
420*320*250mm
60.00cm * 70.00cm * 30.00cm
9.8kg
CE
CE, SGS
Carton Box, Plastic Bagsor as Your Payment
China
China Coal
China Coal
Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Co, CO2, Hc, O2, No
Contact the supplier about freight and estimated delivery time.
Customized
FOB
Fob
HPC501
Hc, Co, CO2, O2
Infrared Absorption Analyzer
LC, T/T, Western Union
Portable
Qingdao, Ningbo,Shanghai,Shenzhen
Support payments in USD
China
Not specified
Not specified
2008-08-01
Not specified
Not specified
LC, T/T, Western Union
FOB
Qingdao, Ningbo,Shanghai,Shenzhen
Alibaba Certification, Cayman Business License, CE Certificate of Gas Detector, CE Certificate of Mine Car, CE Certificate of Packaging Machine, CE Certificate of Railway Maintenance Machine, CE Certificate of Winch, CE for Drills Equipment, Crawler Crane CE Certificate, ISO, MA Certificate, Mining Car CE Certificate, Rock Loader CE Certificate, Self Rescuer CE, SGS, Shaft Sinking Winch CE Certificate, Sliding Stop Buffer Utility Model Patent Certificate, Spiral Handle Tight Sealing Mine Door Utility Model Patent Certificate, TUV SUD Certification and Testing


An Exhaust Gas Analyzer (EGA), also commonly known as an emission analyzer, is a sophisticated diagnostic instrument designed to measure the concentration of specific gases present in the exhaust stream of internal combustion engines. It is a critical tool for automotive repair, environmental compliance testing, and engine performance research.
The primary function of the analyzer is to quantify key pollutant gases, most notably hydrocarbons (HC), carbon monoxide (CO), carbon dioxide (CO2), and oxygen (O2). For modern vehicles equipped with catalytic converters, it also precisely measures oxides of nitrogen (NOx). The device operates by extracting a sample of exhaust gas, typically via a probe inserted into the vehicle's tailpipe. This sample is conditioned (filtered, dried, and cooled) before being channeled into a series of dedicated sensors. Each gas component is detected using specific technologies: Non-Dispersive Infrared (NDIR) sensors for HC, CO, and CO2; electrochemical cells for O2 and NOx.

| Model | HPC501 |
| Measurement Range | HC: 0 ~ 10,000 ppm (vol) CO: 0 ~ 10% (vol) CO2: 0 ~ 20% (vol) O2: 0 ~ 25% (vol) NOx: 0 ~ 5,000 ppm (vol) λ (Air-Fuel Ratio): 0.50 ~ 3.00 COcor (Corrected CO): 0 ~ 10% (vol) |
| Indication Error | HC: ±12 ppm (Absolute) or ±5% (Relative) CO: ±0.06% (Absolute) or ±5% (Relative) CO2: ±0.5% (Absolute) or ±5% (Relative) O2: ±0.1% (Absolute) or ±5% (Relative) NOx: ±25 ppm (Absolute) or ±4% (Relative) |
| Repeatability | Error ≤ ±2% |
| Stability | Automatic zero calibration; Span drift ≤ ±3% |
| Resolution | HC: 1 ppm CO: 0.01% CO2: 0.1% O2: 0.01% NOx: 1 ppm λ: 0.01 |
| Response Time | ≤ 10 seconds (for 95% response) |
| Warm-up Time | 8 minutes (3-minute emergency warm-up available) |
| Output | Direct digital display. Supports optional printer for output of gas names, max concentrations, test time/date, etc. Equipped with interfaces for computer networking. |
| Environmental Conditions | Operating Temperature: -5°C to +50°C Relative Humidity: ≤ 90% |
| Power Supply | AC 100-240V, 50/60Hz, or DC 12V (requires optional power inverter) |
| Power Consumption | 40 VA |
| Dimensions (L × W × H) | 420 mm × 310 mm × 170 mm |
| Weight | Approx. 9 kg |
| Model | HPC500 |
| Measurement Range | HC:0~10000×10-6(ppm)vol CO:0~10×10-2(%)vol CO2:0~20×10-2(%)vol O2: 0~25×10-2(%)vol NOx:0~5000×10-6(ppm)vol λ:0.50~3.00 COcor:0~10×10-2(%)vol |
| Engine Speed | 0-9990rpm |
| Oil Temperature | 0-150ºC |
| Indication Error | HC: ±12 × 10^-6(ppm) vol (absolute error) or ±5% (relative error) CO: ±0.06 × 10^-²(%) vol (absolute error) or ±5% (relative error) CO2: ±0.5 × 10^-²(%) vol (absolute error) or ±5% (relative error) O2: ±0.1 × 10^-² (%) vol (absolute error) or ±5% (relative error) NOx: ±25 × 10^-6(ppm) vol (absolute error) or ±4% (relative error) |
| Repeatability | Repeat error ≤ ±2% |
| Stability | Automatic zero calibration; span drift ≤ ±3% |
| Resolution | HC:1×10-6(ppm)vol CO: 0.01×10-2(%)vol CO2: 0.1×10-2(%)vol O2: 0.01×10-2(%)vol NOx:1×10-6(ppm)vol λ:0.01 |
| Engine Speed | 10rpm |
| Oil Temperature | 0.1ºC |
| Response Time | 95% response ≤ 10 seconds |
| Warm-up Time | 8 minutes (emergency testing possible after 3-minute preheat) |
| Output Method | Can display on screen or print maximum, average, and minimum gas concentrations, license plate number, test time, date, engine speed, oil temperature, λ, and COcor values. Equipped with interface for computer networking. |
| Environmental Conditions | Temperature: -5 to 50°C; relative humidity ≤ 90% |
| Power Supply | AC 100-240 V, 50/60 Hz, or DC 12 V (with optional power inverter) |
| Power consumption | 40 VA |
| Dimensions | 420 mm (L) × 310 mm (W) × 170 mm (H) |
| Weight | Approximately 9 kg |
| Model | HPC518 |
| Measurement Range | HC: 0-10000×10^-6ppm vol (Gasoline, n-Hexane equivalent) or C3H8: 0-20000×10^-6ppm vol (LPG, Propane equivalent) |
| CO: 0-10×10^-²% vol | |
| CO2: 0-20×10^-²% vol | |
| O2: 0-25×10^-²% vol | |
| NOx: 0-5000×10^-6ppm vol | |
| λ (Lambda): 0.50-3.00 COcor | |
| 0-10×10^-²% vol | |
| Indication Error | HC (0-2000 ppm): ±4 ppm or ±3% |
| HC (2001-5000 ppm): ±5% | |
| HC (5001-10000 ppm): ±10% | |
| CO (0.00-10.00×10^-²%): ±0.02×10^-²% or ±3% | |
| CO (10.01-14.00×10^-²%): ±5% | |
| CO2(0.0-16.0×10^-²%): ±0.3×10^-²% or ±3% | |
| CO2 (16.1-20.0×10^-²%): ±5% | |
| O2: ±0.1×10^-²% or ±5% | |
| NOx: ±25 ppm or ±4% | |
| Stability | Automatic zero calibration, span drift ≤ ±3% |
| Repeatability | Repeat error ≤ ±2% |
| Resolution | HC: 1 ppm; CO: 0.01×10^-²%; CO2: 0.1×10^-²%; O2: 0.01×10^-²%; NOx: 1 ppm; λ: 0.01; RPM: 10 r/min; Oil Temp: 0.1 ºC |
| Response Time | ≤10 s (95% response) |
| Warm-up Time | 3 min (1 min for emergency testing) |
| Operating Conditions | Temperature: -5 to 50 ºC |
| Humidity: ≤90% | |
| Sensor Lifetime | Oxygen sensor: approx. 2 years |
| NOx sensor: approx. 14 months | |
| Power Supply | Built-in battery; DC 12 V vehicle power; AC 100-240 V, 50/60 Hz |
| Power Consumption | < 50 VA |
| Dimensions | 520×360×250 mm (L×W×H) |
| Model | HPC302 |
| Measuring Range | HC: 0-10000×10^-6ppm vol |
| CO: 0-10×10^-²% vol | |
| NOx: 0-4000×10^-6ppm vol | |
| Indicating Error | HC: ±12×10^-6ppm (absolute error) or ±5% (relative error) |
| CO: ±0.06×10^-²% (absolute error) or ±5% (relative error) | |
| NOx: ±25×10^-6ppm (absolute error) or ±4% (relative error) | |
| Stability | Span drift ≤ ±3% |
| Repeatability | ≤ ±2% |
| Resolution | HC: 1×10^-6ppm vol |
| CO: 0.01×10^-²% vol | |
| NOx: 1×10^-6ppm vol | |
| Response Time | ≤10 s (95% response) |
| Preheating Time | 8 min (3 min for emergency detection) |
| Output Mode | Digital direct reading; printer connection available; gas name, maximum value, average value, minimum value, test time and date printable; computer network interface supported |
| Operating Conditions | Temperature: -5 to 50 ºC |
| Relative humidity: ≤90% | |
| Power Supply | AC 100-240 V, 50/60 Hz or DC 12 V (with power inverter) |
| Power Consumption | 40 VA |
| Dimensions | 420 × 310 × 170 mm (L×W×H) |
| Weight | 9 kg |
| Model | HPC400 |
| Measuring range | HC: 0~10000×10-6(ppm)vol,CO: 0~10×10-2(%)vol ) CO2: 0~20×10-2(%)vol, O2: 0~25×10-2(%)vol R.M.P: 0~9999r.m.p OIL TEMP:0~150ºC Lambda: 0.50~3.00 COcor:0~10×10-2(%)vol |
| Indicatingerror | HC±12×10-6(ppm)vol ( absolute error ) or±5% ( relative error ) CO±0.06×10-2(%)vol ( absolute error ) or±5% ( relative error ) CO2±0.5×10-2(%)vol ( absolute error ) or±5% ( relative error ) O2±0.1×10-2(%)vol ( absolute error ) or±5% ( relative error ) |
| Stability | moment drift≤±3% |
| Repeatability | ≤±2% |
| Resolution | HC:1×10-6(ppm)vol, CO: 0.01×10-2(%)vol CO2: 0.1×10-2(%)vol, O2: 0.01×10-2(%)vol, Lambda: 0.01 R.P.M:10r.p.m, OIL TEMP:0.1ºC |
| Response time | 95% response is not more than 10 seconds |
| Preheating time | 8min ( preheating 3min emergency detection ) |
| Output Method | Output mode can display, print gas concentration maximum value, average value, the minimum value of the license plate number, test time, date, speed, temperature and COcor value of lambda, can interface with computer networking |
| And-use temperature | -5~50°C, Relative humidity: ≤90% |
| Power | AC100~240V 50/60Hz or DC12V( Add power inverter) Power consumption: 40VA |
| Dimension | 420 (L )×310(W)×170(H)mm |
| Weight | 9kg |
| Model | HPC401 |
| Measuring range | HC:0~10000×10-6(ppm)vol CO:0~10×10-2(%)vol CO2:0~20×10-2(%)vol O2: 0~25×10-2(%)vol λ:0.50~ 3.00 COcor:0~10×10-2(%)vol |
| Indicatingerror | HC±12×10-6(ppm)vol ( absolute error ) or±5% ( relative error ) CO±0.06×10-2(%)vol ( absolute error ) or±5% ( relative error ) CO2±0.5×10-2(%)vol ( absolute error ) or±5% ( relative error ) O2±0.1×10-2(%)vol ( absolute error ) or±5% ( relative error ) |
| Stability | moment drift≤±3% |
| Repeatability | Repeatability≤±2% |
| Resolution | HC:1×10-6(ppm)vol, CO: 0.01×10-2(%)vol CO2: 0.1×10-2(%)vol, O2: 0.01×10-2(%)vol, Lambda: 0.01 R.P.M:10r.p.m, OIL TEMP:0.1ºC |
| Response time | 95% response is not more than 10 seconds |
| Preheating time | 8min ( preheating 3min emergency detection ) |
| Output mode | digital direct reading, gases can be attached printer name, in accordance with national standards and the average concentration of the maximum value, test time, date. Can interface with computer networking. |
| And-use temperature | -5~50°C, Relative humidity: ≤90% |
| Power | AC100~240V 50/60Hz or DC12V( Add power inverter)Power consumption: 40VA |
| Dimension | 420 (L )×310(W)×170(H)mm |
| Weight | 9kg |












Supplier Review
Summary by Vivian
TRUST STARS
3.7/5
0 Reviews
Company Verification
0/4
Profile Completeness
56%
Avg. Product Score
0/5
Responsiveness
0%
Certification
Alibaba Certification, Cayman Business License, CE Certificate of Gas Detector, CE Certificate of Mine Car, CE Certificate of Packaging Machine
You can contact verified China supplier Shandong China Coal Industrial & Mining Supplies Group Co., Ltd. through platforms like Freshdi.com to purchase Toxic Combustible Vehicle Exhaust Gas Analyzer. For direct inquiries, please contact Miss Linda Zhang, the company’s representative. The supplier has a 3.7-star rating on Freshdi and has verified. You’ll receive product details, pricing, and shipping terms directly from supplier.
For Toxic Combustible Vehicle Exhaust Gas Analyzer, Shandong China Coal Industrial & Mining Supplies Group Co., Ltd. accepts LC, T/T, Western Union as the preferred payment method, the trade term is FOB, and shipments are typically arranged from port Qingdao, Ningbo,Shanghai,Shenzhen, ensuring secure and timely international delivery.
The supplier Shandong China Coal Industrial & Mining Supplies Group Co., Ltd. offers Toxic Combustible Vehicle Exhaust Gas Analyzer at negotiation.
Toxic Combustible Vehicle Exhaust Gas Analyzer is sourced from China and meets international export standards. Key specifications include: Certification: CE, Production Capacity: 1000 Sets Per Month, Payment Methods: Support payments in USD, Transport Package: Carton Box, Plastic Bagsor as Your Payment, Customized: Customized, Specification: CE, SGS, Trade Term: FOB, Payment Term: LC, T/T, Western Union
You are viewing details for Toxic Combustible Vehicle Exhaust Gas Analyzer. The information provided here is either posted directly by the supplier, who is responsible for its accuracy, or collected by Freshdi AI from publicly available sources. Freshdi strives to make product information as useful and reliable as possible, but we do not guarantee complete accuracy. If you notice any incorrect or misleading details, please use the Report Product option so our team can review and address it quickly.

$1,000
/ Piece
Min. order: 1 Piece
Miss Linda Zhang
Year Established: 2008-08-01