
Share on
5 views
Set
Negotiable
1 Set
D/P, L/C, T/T
CFR, CIF, EXW, FOB
Qingdao, China, Cn (QID)
Key Takeaways
Freshdi AI is analyzing this product...
143–376 Kva
20 Kva To 5000 Kva
20–313 Kva
38–1750 Kva
41–1650 Kva
55–715 Kva
625–5000 Kva
Ats Control, Island Operation, Parallel Operation, Synchronization Control, Grid-connection Control, Chp-ready
China
Chp Projects, Hotels, Hospitals, Greenhouses, Sewage Treatment Plants
Enerzip
Enerzip Engine, Doosan Powered, Man Powered, Cummins Powered, Weichai Powered, Cnpc Jichai Powered
Factories, Cold Stores, Commercial Buildings, Mixed Industrial Loads
Factories, Commercial Buildings, Industrial Parks, Oil And Gas Fields, Hotels, Hospitals, Greenhouses, Sewage Treatment Plants, On-site Power Stations
Factories, Commercial Buildings, Industrial Power Projects
Farms, Workshops, Restaurants, Small Factories, Shops
Fuel Gas Conditions, Required Power Output, Operating Mode, Load Type, Installation Environment, Control System Requirements
Gas Consumption Data Should Be Treated As Indicative Values. Actual Gas Consumption Depends On Gas Composition, Lower Heating Value, Engine Calibration, Operating Load And Site Conditions.
Gas Type, Inlet Gas Pressure, Pressure Stability, Methane Content, Moisture, Impurities, Load Profile, Operating Hours, Ambient Temperature, Altitude, Ventilation Conditions, Installation Type, Ats, Parallel Operation, Grid-connection Requirements
Industrial Plants, Oil And Gas Projects, Chp, Peak Shaving, Multi-unit Systems
Natural Gas Generator Set
Oilfield Gas Power, Flare Gas Utilization, On-site Power Stations
Open Type, Silent Type, Containerized Type
Standby Power, Prime Power, Long-duration Operation, Chp Projects, Oilfield Power Supply, Commercial Buildings, Industrial Plants, On-site Power Station

3.4
China
Exporter/Wholesaler, Non-food manufacturing, Service Provider
Weifang Comprehensive Bonded Zone, Weifang, Shandong Province, China
Avg Response Time
≤ 1h
Response Rate
7%
Inquiry Open Rate
93%
Total inquiries received
14
Based on the information provided by the supplier.
Bolivia, Plurinational State of
Bosnia and Herzegovina
Bouvet Island
Cape Verde
El Salvador
Central America & Caribbean
26%
Oceania
23%
Western Europe
22%
Eastern Europe
16%
West Africa
13%
Verify work email
By Freshdi.com
Verify phone number
Buyer Verification Team
Verify account email
By Freshdi.com
Verify business documents
Enerzip natural gas generator sets are designed for standby power, prime power, long-duration operation, CHP projects, oilfield power supply, commercial buildings, industrial plants and on-site power station applications. The product range covers 20 kVA to 5000 kVA, supporting small commercial power demand, medium industrial applications and megawatt-class power generation projects.
Each natural gas generator set should be selected according to real site conditions, not only by kVA rating. Key factors include gas type, inlet gas pressure, pressure stability, methane content, moisture, impurities, load profile, operating hours, ambient temperature, altitude, ventilation conditions, installation type, ATS, parallel operation and grid-connection requirements.
Enerzip natural gas generator sets can be configured as open type, silent type or containerized type. ATS control, island operation, parallel operation, synchronization control, grid-connection control and CHP-ready options can be provided according to project requirements.
These gas generator sets are suitable for factories, commercial buildings, industrial parks, oil and gas fields, hotels, hospitals, greenhouses, sewage treatment plants, on-site power stations and other locations with stable gas supply.
SeriesPower RangeEngine PlatformTypical Applications
E Series
20–313 kVA
Enerzip Engine
Farms, workshops, restaurants, small factories, shops
D Series
143–376 kVA
Doosan Powered
Factories, cold stores, commercial buildings, mixed industrial loads
MA Series
55–715 kVA
MAN Powered
CHP projects, hotels, hospitals, greenhouses, sewage treatment plants
C Series
41–1650 kVA
Cummins Powered
Industrial plants, oil and gas projects, CHP, peak shaving, multi-unit systems
W Series
38–1750 kVA
Weichai Powered
Factories, commercial buildings, industrial power projects
J Series
625–5000 kVA
CNPC Jichai Powered
Oilfield gas power, flare gas utilization, on-site power stations
Gas consumption data should be treated as indicative values. Actual gas consumption depends on gas composition, lower heating value, engine calibration, operating load and site conditions.
For quotation and model selection, the final configuration should be confirmed based on fuel gas conditions, required power output, operating mode, load type, installation environment and control system requirements.
No reviews yet
Be the first to share your experience - your feedback helps other buyers trade with confidence.
You are viewing details for Industrial Natural Gas Generator Set for Standby, Prime Power and CHP Applications. The information provided here is either posted directly by the supplier, who is responsible for its accuracy, or collected by Freshdi AI from publicly available sources. Freshdi strives to make product information as useful and reliable as possible, but we do not guarantee complete accuracy. If you notice any incorrect or misleading details, please use the Report Product option so our team can review and address it quickly.

Negotiable
Min. order: Negotiable
Bob (Sale/ Marketing/ Sourcing Manager)
Active
Response Rate: 7%
Avg Response Time: ≤ 1h
Year Established: 2011
Business type
Exporter/Wholesaler, Non-food manufacturing, Service Provider
Main Export Markets